This table is compiled according to EUROCONTROL ASTERIX CAT002, Part 2b, Monoradar Service Messages, Edition 1.0, 1997.11.01.
- M stands for mandatory,
- O for optional,
- X for never present.
Item | Message Type | ||||
001 North marker |
002 Sector crossing |
003 South marker |
008 Activation of blind zone filtering |
009 Stop of blind zone filtering |
|
I002/000 Message Type |
M | M | M | M | M |
I002/010 Data Source Identifier |
M | M | M | M | M |
I002/020 Sector Number |
X | M | X | X | X |
I002/030 Time of Day |
O | O | O | O | O |
I002/041 Antenna Rotation Period |
O | O | X | X | X |
I002/050 Station Configuration Status |
O | O | O | X | X |
I002/060 Station Processing Mode |
O | O | O | X | X |
I002/070 Plot Count Values |
O | O | X | X | X |
I002/080 Warning/Error Conditions |
O | O | O | X | X |
I002/090 Collimation Error |
O | O | X | X | X |
I002/100 Dynamic Window — Type 1 |
X | X | X | M | X |